Siemens accessori per computer V3 Manuale

Manuali PDF
180 Pagine Italiano

Siemens accessori per computer V3
Configuring the AS-Interface safety monitor
4.3 Creating and changing a configuration
ASIMON V3 - Configuration software for AS-Interface safety monitor
Programming and Operating Manual, Edition 09/2008, GWA 4NEB 333 1558 02 DS 02
119
Assign the dummies for restart and reset of error condition the desired devices by using
drag&drop to move devices from the icon library onto the dummies.
Once the dummies are assigned the appropriate devices, you can make further settings for the
reset of error condition and for restart by reopening the input mask of the output device.
To do this, click the output device with the right mouse button, select the Edit command from
the pop-up menu which opens and click the AS-iS control tab in the input mask.
Input mask
In the Reset of error condition and Restart areas in the Help signals part of the window, you
can define in detail which signals result in an activation of the reset of error condition and in
restart of the safe actuator.
Available for selection for activating the reset of error condition are:
- Once on OFF --> ON
- Once on ON --> OFF
- Once on change of state
Available for selection for activating the restart are:
- Continuous while ON
- Continuous while OFF
- Continuous while ON and OFF
- Once on OFF --> ON
- Once on ON --> OFF
- Once on change of state
Define the events for activating the reset of error condition and restart and confirm your entry
with OK.
Note
For an automatic restart, simply assign the restart dummy the TRUE system device.