Electric supply: 220-240 V ~ 50/60 Hz
Appliance cate-
gory:
II2E+3+ (BE)
I2E (LU)
Gas connection: R 1/2"
Appliance class: 3
BYPASS DIAMETERS
BURNER Ø BYPASS 1/100 mm
Triple Crown 57
Rapid 42
Semi-rapid 32
Auxiliary 28
GAS BURNERS FOR NATURAL GAS G20/G25 20/25 mbar (BE) - G20 20 mbar (LU)
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Triple Crown 4,0 1,4 146
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar G31 37 mbar
Triple
Crown
4,0 1,4 98 291 286
Rapid 2,8 0,75 86 204 200
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
ENERGY EFFICIENCY
PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification ZGG75524XA